<div class="definition"><div class="short_definition">(Also known as hygrometric formula.) The semi-empirical relation giving  the [[vapor pressure]] in terms of the [[barometer]] and [[psychrometer]] readings.</div><br/> <div class="paragraph">For temperatures in degrees Celsius, this formula is  <div class="display-formula"><blockquote>[[File:ams2001glos-Pe60.gif|link=|center|ams2001glos-Pe60]]</blockquote></div> where ''T'' and ''T''<sub>''w''</sub> are the [[dry-bulb]] and [[wet-bulb temperatures]], respectively; ''e'' is the vapor pressure;  ''e''<sub>''s''</sub>(''T''<sub>''w''</sub>) is the [[saturation vapor pressure]] at the wet-bulb temperature; and ''p'' is [[pressure]]. For  temperatures below [[freezing]], with the wet bulb covered with [[ice]], 6.60 &times; 10<sup>-4</sup> is replaced by,  approximately, 5.82 X 10<sup>-4</sup>.</div><br/> </div>
<div class="definition"><div class="short_definition">(Also known as hygrometric formula.) The semi-empirical relation giving  the [[vapor pressure]] in terms of the [[barometer]] and [[psychrometer]] readings.</div><br/> <div class="paragraph">For temperatures in degrees Celsius, this formula is  <div class="display-formula"><blockquote>[[File:ams2001glos-Pe60.gif|link=|center|ams2001glos-Pe60]]</blockquote></div> where ''T'' and ''T''<sub>''w''</sub> are the [[dry-bulb temperature|dry-bulb]] and [[wet-bulb temperatures]], respectively; ''e'' is the vapor pressure;  ''e''<sub>''s''</sub>(''T''<sub>''w''</sub>) is the [[saturation vapor pressure]] at the wet-bulb temperature; and ''p'' is [[pressure]]. For  temperatures below [[freezing]], with the wet bulb covered with [[ice]], 6.60 &times; 10<sup>-4</sup> is replaced by,  approximately, 5.82 X 10<sup>-4</sup>.</div><br/> </div>
</div>
</div>



Latest revision as of 16:41, 25 April 2012



psychrometric formula

(Also known as hygrometric formula.) The semi-empirical relation giving the vapor pressure in terms of the barometer and psychrometer readings.

For temperatures in degrees Celsius, this formula is
ams2001glos-Pe60
where T and Tw are the dry-bulb and wet-bulb temperatures, respectively; e is the vapor pressure; es(Tw) is the saturation vapor pressure at the wet-bulb temperature; and p is pressure. For temperatures below freezing, with the wet bulb covered with ice, 6.60 × 10-4 is replaced by, approximately, 5.82 X 10-4.


Copyright 2024 American Meteorological Society (AMS). For permission to reuse any portion of this work, please contact permissions@ametsoc.org. Any use of material in this work that is determined to be “fair use” under Section 107 of the U.S. Copyright Act (17 U.S. Code § 107) or that satisfies the conditions specified in Section 108 of the U.S.Copyright Act (17 USC § 108) does not require AMS’s permission. Republication, systematic reproduction, posting in electronic form, such as on a website or in a searchable database, or other uses of this material, except as exempted by the above statement, require written permission or a license from AMS. Additional details are provided in the AMS Copyright Policy statement.